How the thickness is worked out
Thickness = R-value needed ÷ R-value per inch
A worked example
Reaching R-38 with fiberglass at R-3.2 per inch takes 11.9 inches. If there are already 4 inches in place, that is R-12.8, so you need another 7.9 inches.
Typical R-values per inch
- Fiberglass batt: about 3.2
- Blown cellulose: about 3.6
- Mineral wool batt: about 4.0
- Open-cell spray foam: about 3.7
- Closed-cell spray foam: about 6.5
- Foam board: about 4.0 for EPS, 5.0 for XPS and 6.0 for polyiso
These are typical figures. Products vary, and blown insulation settles, so use the number on the label or the bag chart.
Good to know
- The R-value your code requires depends on your climate zone and on whether it is an attic, wall or floor.
- Compressing a batt lowers its total R-value. A thick batt squeezed into a shallow cavity does not perform as labelled.
- Air sealing matters as much as R-value. Seal gaps and penetrations before you insulate.