Attic ventilation calculator

Find how much vent area your attic needs, how to split it between intake and exhaust, and how many vents that means.

Example: A house has ice dams and a hot attic. Check whether the existing soffit and ridge vents add up to enough vent area, and how many more are needed.

Your numbers

Net free area, or NFA, is the open area of a vent after louvers and screens. It is printed on the vent or its packaging in square inches.

ft
ft
150 is the standard rule. Some codes allow 300.
sq in
A soffit vent, for example.
sq in
A box vent, for example.
Drawn from your numbers. It redraws as you type.
  • Total vent area0
  • Intake, and the same for exhaust0
  • Intake vents0
  • Exhaust vents0
  • Attic floor area0

Attic ventilation calculator. Estimate from everysinglecalculator.com

Materials list
ItemBuyHow it was worked out

How vent area is worked out

The usual rule is 1 square foot of net free vent area for every 150 square feet of attic floor. Half goes low at the eaves as intake and half goes high near the ridge as exhaust.

Vent area in square inches = attic floor area ÷ 150 × 144

A worked example

A 40 by 30 foot attic is 1,200 square feet. Divided by 150, that is 8 square feet of vent area, or 1,152 square inches. Half of that, 576 square inches, is intake and half is exhaust. With soffit vents rated at 9 square inches each you need 64. With box vents at 50 square inches you need 12.

Good to know

  • Many codes allow the 1 to 300 ratio when the vents are balanced between high and low, and in some climates when the ceiling has a vapor retarder. Check your local code before using it.
  • If you cannot balance exactly, put the extra on the intake side. Too much exhaust can pull conditioned air out of the house.
  • Do not mix exhaust types on one roof. A ridge vent and box vents together can short-circuit the airflow.
  • Keep insulation from blocking the soffit vents. Baffles between the rafters hold a clear path.

Common questions

How do I size a ridge vent?

Ridge vent is rated per linear foot, commonly around 18 square inches. Enter that as the exhaust figure and the answer is the feet of ridge vent you need.

Does a cathedral ceiling follow the same rule?

The ratio is the same, but each rafter bay has to be vented from eave to ridge. Unvented assemblies with spray foam follow different rules.

How we know this calculator is right

Before this calculator went on the site, 11 answers were worked out separately from its code, by hand or straight from the formula above. Each time this page loads, your own browser runs the calculator on those same numbers and compares. Turn on JavaScript to see the comparison.

See every check
Numbers usedResultWorked out separatelyThis calculator

What this proves: the calculator does the arithmetic of the formula shown, correctly. What it cannot prove: your measurements, or figures such as coverage per bag, waste and spacing, which are typical starting values you can change. Go by the product label and your local code.

Used by: roofers, hvac technicians, insulation installers.